The following table is a summary of two separate - before and after - tests, on an oily water separator system in Cape Town. The first test was done on the 12th May 2009, and the follow up test on the 8th June 2009.

 

These tests were conducted by an independent laboratory - a division of Eskom. We have copies of the original documentation for those who wish to see them. We are also happy to arrange for you to use this or any other laboratory of your choice for testing your own site effluent or the site of spillage.

 

The test results were given the following remarks:

•Before test - Water of this quality is unsuitable for discharge into a sewer. COD exceeds the limit. Oil / sludge traps should be cleaned on a regular basis.
•After test - Water of this quality is acceptable for discharge into a sewer.


Test Results Table
------------------------

 

 Analyte

 Value Before
Value After
 Unit  Minimum  Maximum  Method
 Cadmium  <0.005  <0.005  mg/l Cd
   5  Eskom No 412
 Chromium  0.1  0.01  mg/l Cr
   10  Eskom No 412
 COD  8740  683  mg/l O2
   5000  HACH P 2/218
 Colour  Turbid  Turbid        
 Conductivity  206  39  mS/m @25 C
   500  SABS 1057
 Copper  2.9  0.63  mg/l Cu
   20  Eskom No 412
 Fat, Grease & Oil
 197  7.7  mg/l    400  SABS 1051
 Iron  16  2.3  mg/l Fe
   50  Eskom No 412
 Lead  1.3  0.18  mg/l Pb
   5  Eskom No 412
 pH
 7.0  6.4  @25 C
 5.5  12  SABS 11
 Suspended Solid
 263  44  mg/l    1000  SABS 1049
 Zinc  16  1.1  mg/l Zn
   30  Eskom No 412
 