Tests

 

The following table is a summary of two separate – before and after – tests, on an oily water separator system in Cape Town. The first test was done on the 12th May 2009, and the follow up test on the 8th June 2009.

 

These tests were conducted by an independent laboratory – a division of Eskom. We have copies of the original documentation for those who wish to see them. We are also happy to arrange for you to use this or any other laboratory of your choice for testing your own site effluent or the site of spillage.

 

The test results were given the following remarks:

•Before test – Water of this quality is unsuitable for discharge into a sewer. COD exceeds the limit. Oil / sludge traps should be cleaned on a regular basis.
•After test – Water of this quality is acceptable for discharge into a sewer.

Test Results Table
————————

 Analyte

 Value Before

Value After

 Unit

 Minimum

 Maximum

 Method

 Cadmium

 <0.005

 <0.005

 mg/l Cd

 5

 Eskom No 412

 Chromium

 0.1

 0.01

 mg/l Cr

 10

 Eskom No 412

 COD

 8740

 683

 mg/l O2

 5000

 HACH P 2/218

 Colour

 Turbid

 Turbid

 Conductivity

 206

 39

 mS/m @25 C

 500

 SABS 1057

 Copper

 2.9

 0.63

 mg/l Cu

 20

 Eskom No 412

 Fat, Grease & Oil

 197

 7.7

 mg/l

 400

 SABS 1051

 Iron

 16

 2.3

 mg/l Fe

 50

 Eskom No 412

 Lead

 1.3

 0.18

 mg/l Pb

 5

 Eskom No 412

 pH

 7.0

 6.4

 @25 C

 5.5

 12

 SABS 11

 Suspended Solid

 263

 44

 mg/l

 1000

 SABS 1049

 Zinc

 16

 1.1

 mg/l Zn

 30

 Eskom No 412